These units are ideal
for PC based control and automation of equipment including sensors,
switches, relays, robotics, and industrial automation systems.
The input ports are
optically isolated. Each input has a 10K 1/2 Watt current limiting
resistor in series with the optoisolator. The inputs can sense voltages
from 6 to 48 VDC. Higher voltages can be sensed by adding another
resistor in series with the input. Each input has a clearly marked LED
located on the board to indicate when a voltage is sensed.
The output ports are
mosfets capable of switching voltages between 6 and 48 VDC. Each output
is configured as a current sink to ground. The outputs are able to
switch up to 2 Amps at 48 VDC. Each output has a clearly marked LED
located on the board to indicate when that output is sinking current.
The RP0000xxxxTBCLDC
uses screw clamp terminal blocks. Each board is bus powered and will
draw a maximum of 125 ma from the USB bus. While not required, it is
recommended that the RP0000xxxxTBCLDC be connected directly to a
computer 's USB port or to a powered USB hub.
The RP0000xxxxTBCLDC
comes with an installation CDROM, manual and a 10 foot USB2.0 cable.
Included on the CDROM are software examples to assist in getting the
RP0000xxxxTBCLDC up and running.
This document maintained
by BCS Ideas .
Material Copyright © 2004-
BCS Ideas
|